Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
IEEE Open J Eng Med Biol ; 5: 32-44, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38445238

RESUMO

High-density multielectrode catheters are becoming increasingly popular in cardiac electrophysiology for advanced characterisation of the cardiac tissue, due to their potential to identify impaired sites. These are often characterised by abnormal electrical conduction, which may cause locally disorganised propagation wavefronts. To quantify it, a novel heterogeneity parameter based on vector field analysis is proposed, utilising finite differences to measure direction changes between adjacent cliques. The proposed Vector Field Heterogeneity metric has been evaluated on a set of simulations with controlled levels of organisation in vector maps, and a variety of grid sizes. Furthermore, it has been tested on animal experimental models of isolated Langendorff-perfused rabbit hearts. The proposed parameter exhibited superior capturing ability of heterogeneous propagation wavefronts compared to the classical Spatial Inhomogeneity Index, and simulations proved that the metric effectively captures gradual increments in disorganisation in propagation patterns. Notably, it yielded robust and consistent outcomes for [Formula: see text] grid sizes, underscoring its suitability for the latest generation of orientation-independent cardiac catheters.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38082627

RESUMO

In this study, a novel unsupervised classification framework for time series of medical nature is presented. This framework is based on the intersection of machine learning, Hilbert Spaces algebra, and signal theory. The methodology is illustrated through the resolution of three biomedical engineering problems: neuronal activity tracking, protein functional classification, and non-invasive diagnosis of atrial flutter (AFL). The results indicate that the proposed algorithms exhibit high proficiency in solving these tasks and demonstrate robustness in identifying damaged neuronal units while tracking healthy ones. Moreover, the application of the framework in protein functional classification provides a new perspective for the development of pharmaceutical products and personalised medicine. Additionally, the controlled environment of the framework in AFL simulation problem underscores the algorithm's ability to encode information efficiently. These results offer valuable insights into the potential of this framework and lay the groundwork for future studies.Clinical relevance- The framework proposed in this study has the potential to yield novel insights into the effects of newly implanted electrodes in the brain. Furthermore, the categorization of proteins by function could facilitate the development of personalised and efficient medicines, ultimately reducing both time and cost. The simulation of atrial flutter also demonstrates the framework's ability to encode information for arrhythmia diagnosis and treatment, which has the potential to lead to improved patient outcomes.


Assuntos
Flutter Atrial , Humanos , Flutter Atrial/diagnóstico , Engenharia Biomédica , Fatores de Tempo , Arritmias Cardíacas , Bioengenharia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38082704

RESUMO

The present study aims to design and fabricate a system capable of generating heterogeneities on the epicardial surface of an isolated rabbit heart perfused in a Langendorff system. The system consists of thermoelectric modules that can be independently controlled by the developed hardware, thereby allowing for the generation of temperature gradients on the epicardial surface, resulting in conduction slowing akin to heterogeneities of pathological origin. A comprehensive analysis of the system's viability was performed through modeling and thermal simulation, and its practicality was validated through preliminary tests conducted at the experimental cardiac electrophysiology laboratory of the University of Valencia. The design process involved the use of Fusion 360 for 3D designs, MATLAB/Simulink for algorithms and block diagrams, LTSpice and Altium Designer for schematic captures and PCB design, and the integration of specialized equipment for animal experimentation. The objective of the study was to efficiently capture epicardial recordings under varying conditions.Clinical relevance- The proposed system aims to induce local epicardial heterogeneities to generate labeled correct signals that can serve as a golden standard for improving algorithms that identify and characterize fibrotic substrates. This improvement will enhance the efficacy of ablation processes and potentially reduce the ablated surface area.


Assuntos
Coração , Animais , Coelhos , Coração/fisiologia , Frequência Cardíaca/fisiologia , Temperatura
4.
Phys Eng Sci Med ; 46(3): 1193-1204, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37358782

RESUMO

High-density catheters combined with Orientation Independent Sensing (OIS) methods have emerged as a groundbreaking technology for cardiac substrate characterisation. In this study, we aim to assess the arrangements and constraints to reliably estimate the so-called omnipolar electrogram (oEGM). Performance was evaluated using an experimental animal model. Thirty-eight recordings from nine retrospective experiments on isolated perfused rabbit hearts with an epicardial HD multielectrode were used. We estimated oEGMs according to the classic triangular clique (4 possible orientations) and a novel cross-orientation clique arrangement. Furthermore, we tested the effects of interelectrode spacing from 1 to 4 mm. Performance was evaluated by means of several parameters that measured amplitude rejection ratios, electric field loop area, activation pulse width and morphology distortion. Most reliable oEGM estimations were obtained with cross-configurations and interelectrode spacings [Formula: see text] mm. Estimations from triangular cliques resulted in wider electric field loops and unreliable detection of the direction of the propagation wavefront. Moreover, increasing interelectrode distance resulted in increased pulse width and morphology distortion. The results prove that current oEGM estimation techniques are insufficiently accurate. This study opens a new standpoint for the design of new-generation HD catheters and mapping software.


Assuntos
Coração , Software , Animais , Coelhos , Estudos Retrospectivos , Eletrodos , Modelos Animais
5.
Comput Biol Med ; 154: 106604, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36709520

RESUMO

OBJECTIVE: The aim of this study is to propose a method to reduce the sensitivity of the estimated omnipolar electrogram (oEGM) with respect to the angle of the propagation wavefront. METHODS: A novel configuration of cliques taking into account all four electrodes of a squared cell is proposed. To test this approach, simulations of HD grids of cardiac activations at different propagation angles, conduction velocities, interelectrode distance and electrogram waveforms are considered. RESULTS: The proposed approach successfully provided narrower loops (essentially a straight line) of the electrical field described by the bipole pair with respect to the conventional approach. Estimation of the direction of propagation was improved. Additionally, estimated oEGMs presented larger amplitude, and estimations of the local activation times were more accurate. CONCLUSIONS: A novel method to improve the estimation of oEGMs in HD grid of electrodes is proposed. This approach is superior to the existing methods and avoids pitfalls not yet resolved. RELEVANCE: Robust tools for quantifying the cardiac substrate are crucial to determine with accuracy target ablation sites during an electrophysiological procedure.


Assuntos
Eletrocardiografia , Coração , Eletrocardiografia/métodos , Coração/fisiologia , Eletrodos , Fatores de Tempo
6.
Physiol Meas ; 43(6)2022 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-35609610

RESUMO

Objective. Detecting different cardiac diseases using a single or reduced number of leads is still challenging. This work aims to provide and validate an automated method able to classify ECG recordings. Performance using complete 12-lead systems, reduced lead sets, and single-lead ECGs is evaluated and compared.Approach. Seven different databases with 12-lead ECGs were provided during thePhysioNet/Computing in Cardiology Challenge2021, where 88 253 annotated samples associated with none, one, or several cardiac conditions among 26 different classes were released for training, whereas 42 896 hidden samples were used for testing. After signal preprocessing, 81 features per ECG-lead were extracted, mainly based on heart rate variability, QRST patterns and spectral domain. Next, a One-versus-Rest classification approach made of independent binary classifiers for each cardiac condition was trained. This strategy allowed each ECG to be classified as belonging to none, one or several classes. For each class, a classification model among two binary supervised classifiers and one hybrid unsupervised-supervised classification system was selected. Finally, we performed a 3-fold cross-validation to assess the system's performance.Main results. Our classifiers received scores of 0.39, 0.38, 0.39, 0.38, and 0.37 for the 12, 6, 4, 3 and 2-lead versions of the hidden test set with the Challenge evaluation metric (CM). Also, we obtained a meanG-score of 0.80, 0.78, 0.79, 0.79, 0.77 and 0.74 for the 12, 6, 4, 3, 2 and 1-lead subsets with the public training set during our 3-fold cross-validation.Significance. We proposed and tested a machine learning approach focused on flexibility for identifying multiple cardiac conditions using one or more ECG leads. Our minimal-lead approach may be beneficial for novel portable or wearable ECG devices used as screening tools, as it can also detect multiple and concurrent cardiac conditions.


Assuntos
Fibrilação Atrial , Cardiopatias , Fibrilação Atrial/diagnóstico , Eletrocardiografia/métodos , Humanos , Aprendizado de Máquina , Processamento de Sinais Assistido por Computador
8.
Comput Methods Programs Biomed ; 200: 105932, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33485078

RESUMO

BACKGROUND AND OBJECTIVES: Macroreentrant atrial tachyarrhythmias (MRATs) can be caused by different reentrant circuits. The treatment for each MRAT type may require ablation at different sites, either at the right or left atria. Unfortunately, the reentrant circuit that drives the arrhythmia cannot be ascertained previous to the electrophysiological intervention. METHODS: A noninvasive approach based on the comparison of atrial vectorcardiogram (VCG) loops is proposed. An archetype for each group was created, which served as a reference to measure the similarity between loops. Methods were tested in a variety of simulations and real data obtained from the most common right (peritricuspid) and left (perimitral) macroreentrant circuits, each divided into clockwise and counterclockwise subgroups. Adenosine was administered to patients to induce transient AV block, allowing the recording of the atrial signal without the interference of ventricular signals. From the vectorcardiogram, we measured intrapatient loop consistence, similarity of the pathway to archetypes, characterisation of slow velocity regions and pathway complexity. RESULTS: Results show a considerably higher similarity with the loop of its corresponding archetype, in both simulations and real data. We found the capacity of the vectorcardiogram to reflect a slow velocity region, consistent with the mechanisms of MRAT, and the role that it plays in the characterisation of the reentrant circuit. The intra-patient loop consistence was over 0.85 for all clinical cases while the similarity of the pathway to archetypes was found to be 0.85 ± 0.03, 0.95 ± 0.03, 0.87 ± 0.04 and 0.91 ± 0.02 for the different MRAT types (and p<0.02 for 3 of the 4 groups), and pathway complexity also allowed to discriminate among cases (with p<0.05). CONCLUSIONS: We conclude that the presented methodology allows us to differentiate between the most common forms of right and left MRATs and predict the existence and location of a slow conduction zone. This approach may be useful in planning ablation procedures in advance.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Átrios do Coração , Humanos , Taquicardia
9.
J Gen Physiol ; 153(2)2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33410862

RESUMO

Ca2+ alternans (Ca-Alts) are alternating beat-to-beat changes in the amplitude of Ca2+ transients that frequently occur during tachycardia, ischemia, or hypothermia that can lead to sudden cardiac death. Ca-Alts appear to result from a variation in the amount of Ca2+ released from the sarcoplasmic reticulum (SR) between two consecutive heartbeats. This variable Ca2+ release has been attributed to the alternation of the action potential duration, delay in the recovery from inactivation of RYR Ca2+ release channel (RYR2), or an incomplete Ca2+ refilling of the SR. In all three cases, the RYR2 mobilizes less Ca2+ from the SR in an alternating manner, thereby generating an alternating profile of the Ca2+ transients. We used a new experimental approach, fluorescence local field optical mapping (FLOM), to record at the epicardial layer of an intact heart with subcellular resolution. In conjunction with a local cold finger, a series of images were recorded within an area where the local cooling induced a temperature gradient. Ca-Alts were larger in colder regions and occurred without changes in action potential duration. Analysis of the change in the enthalpy and Q10 of several kinetic processes defining intracellular Ca2+ dynamics indicated that the effects of temperature change on the relaxation of intracellular Ca2+ transients involved both passive and active mechanisms. The steep temperature dependency of Ca-Alts during tachycardia suggests Ca-Alts are generated by insufficient SERCA-mediated Ca2+ uptake into the SR. We found that Ca-Alts are heavily dependent on intra-SR Ca2+ and can be promoted through partial pharmacologic inhibition of SERCA2a. Finally, the FLOM experimental approach has the potential to help us understand how arrhythmogenesis correlates with the spatial distribution of metabolically impaired myocytes along the myocardium.


Assuntos
Cálcio , Miócitos Cardíacos , Cálcio/metabolismo , Sinalização do Cálcio , Miócitos Cardíacos/metabolismo , Canal de Liberação de Cálcio do Receptor de Rianodina/metabolismo , Retículo Sarcoplasmático/metabolismo
10.
Comput Methods Programs Biomed ; 188: 105296, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31918194

RESUMO

BACKGROUND AND OBJECTIVE: A heterogenous expression characterizes arrhythmogenic cardiomyopathy (AC). The evaluation of regional wall movement included in the current Task Force Criteria is only qualitative and restricted to the right ventricle. However, a strain-based approach could precisely quantify myocardial deformation in both ventricles. We aim to define and modelize the strain behavior of the left ventricle in AC patients with left ventricular (LV) involvement by applying algorithms such as Principal Component Analysis (PCA), clustering and naïve Bayes (NB) classifiers. METHODS: Thirty-six AC patients with LV involvement and twenty-three non-affected family members (controls) were enrolled. Feature-tracking analysis was applied to cine cardiac magnetic resonance imaging to assess strain time series from a 3D approach, to which PCA was applied. A Two-Step clustering algorithm separated the patients' group into clusters according to their level of LV strain impairment. A statistical characterization between controls and the new AC subgroups was done. Finally, a NB classifier was built and new data from a small evolutive dataset was predicted. RESULTS: 60% of AC-LV patients showed mildly affected strain and 40% severely affected strain. Both groups and controls exhibited statistically significant differences, especially when comparing controls and severely affected AC-LV patients. The classification accuracy of the strain NB classifier reached 82.76%. The model performance was as good as to classify the individuals with a 100% sensitivity and specificity for severely impaired strain patients, 85.7% and 81.1% for mildly impaired strain patients, and 69.9% and 91.4% for normal strain, respectively. Even when the severely affected LV-AC group was excluded, LV strain showed a good accuracy to differentiate patients and controls. The prediction of the evolutive dataset revealed a progressive alteration of strain in time. CONCLUSIONS: Our LV strain classification model may help to identify AC patients with LV involvement, at least in a setting of a high pretest probability, such as family screening.


Assuntos
Arritmias Cardíacas/diagnóstico , Cardiomiopatias/diagnóstico , Diagnóstico por Computador/métodos , Ventrículos do Coração/fisiopatologia , Adulto , Idoso , Algoritmos , Teorema de Bayes , Análise por Conglomerados , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Análise de Componente Principal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
11.
J Physiol Biochem ; 75(2): 173-183, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30887428

RESUMO

Metabolic syndrome (MetS) describes a condition associated with multiple diseases concomitantly such as diabetes, hypertension, obesity, and dyslipidemia. It has been linked with higher prevalence of cardiovascular disease, atrial fibrillation, and sudden cardiac death. One of the underlying mechanisms could be altered automaticity, which would reflect modifications of sinus node activity. These phenomena can be evaluated analyzing the components of heart rate variability (HRV). Our aim was to examine the modifications of sinus node variability in an isolated heart model of diet-induced obesity and MetS. Male NZW rabbits were randomly assigned to high-fat (HF, n = 8), control (HF-C, n = 7), high-fat, high-sucrose (HFHS, n = 9), and control (HFHS-C, n = 9) groups, fed with their respective diets during 18/28 weeks. After euthanasia, their hearts were isolated in a Langendorff system. We recorded 10-15 min of spontaneous activity. Short RR time series were analyzed, and standard HRV parameters were determined. One-way ANOVA, Kruskal-Wallis test, and bivariate correlation were used for statistical analysis (p < 0.05). We did find an increase in the complexity and irregularity of intrinsic pacemaker activity as shown by modifications of approximate entropy, sample entropy, minimum multiscale entropy, and complexity index in HFHS animals. Even though no differences were found in standard time and frequency-domain analyses, spectral heterogeneity increased in HFHS group. Animal weight and glucose intolerance were highly correlated with the modifications of intrinsic pacemaker variability. Finally, modifications of intrinsic HRV seemed to be reliant on the number of components of MetS present, given that only HFHS group showed significant changes towards an increased complexity and irregularity of intrinsic pacemaker variability.


Assuntos
Frequência Cardíaca , Síndrome Metabólica/fisiopatologia , Obesidade/fisiopatologia , Nó Sinoatrial/fisiopatologia , Animais , Dieta Hiperlipídica/efeitos adversos , Masculino , Síndrome Metabólica/etiologia , Obesidade/etiologia , Coelhos , Fatores de Tempo
12.
Int J Cardiol ; 274: 237-244, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30228020

RESUMO

BACKGROUND: Diagnostic Task Force Criteria (TFC) for arrhythmogenic cardiomyopathy (AC) exhibit poor performance for left dominant forms. TFC only include right ventricular (RV) dysfunction (akinesia, dyssynchrony, volumes and ejection fraction). Moreover, cardiac magnetic resonance imaging (CMRI) assessment of left ventricular (LV) dyssynchrony has hitherto not been described. Thus, we aimed to comprehensively characterize LV CMRI behavior in AC patients. METHODS: Thirty-five AC patients with LV involvement and twenty-three non-affected family members (controls) were enrolled. Feature-tracking analysis was applied to cine CMRI to assess LV ejection fraction (LVEF), LV end-systolic and end-diastolic volume indexes, strain values and dyssynchrony. Regions with more frequent strain and dyssynchrony impairment were also studied. RESULTS: Radial dyssynchrony and LVEF were selected (sensitivities 54.3% and 48.6%, respectively at 100% specificity), with a threshold of 70 ms for radial dyssynchrony and 48.5% for LVEF. 71.4% of patients exceeded these thresholds (31.4% both, 22.9% only dyssynchrony and 17.1% only LVEF). Considering these cut-off values as a novel combined criterion, 30% of patients with 'borderline' or 'possible' AC following 2010 TFC would move to a 'definite' AC diagnosis. Strain was globally impaired whereas dyssynchronous regions were more often apical and located at the inferolateral wall. CONCLUSIONS: Mirroring the RV evaluation, we suggest including LVEF and LV dyssynchrony to improve the diagnosis of AC. Two independent mechanisms can be claimed in AC patients with LV involvement: 1) decreased myocardial deformation with global LV affectation and 2) delayed myocardial contraction at localized regions.


Assuntos
Displasia Arritmogênica Ventricular Direita/complicações , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda/fisiologia , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Diástole , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
14.
Ann Transplant ; 22: 285-295, 2017 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-28484204

RESUMO

BACKGROUND Cardioplegic arrest is a common procedure for many types of cardiac surgery, and different formulations have been proposed to enhance its cardio-protective effect. Hydrogen sulfide is an important signaling molecule that has cardio-protective properties. We therefore studied the cardio-protective effect of hydrogen sulfide in cardiac cell culture and its potential therapeutic use in combination with cardioplegia formulations. MATERIAL AND METHODS We added hydrogen sulfide donor GYY4137 to HL-1 cells to study its protective effect in nutrient starved conditions. In addition, we tested the potential use of GYY4137 when it is added into two different cardioplegia formulations: Cardi-Braun® solution and del Nido solution in an ex vivo Langendorff perfused rat hearts model. RESULTS We observed that eight-hour pre-treatment with GYY4137 significantly suppressed apoptosis in nutrient-starved HL-1 cells (28% less compared to untreated cells; p<0.05), maintained ATP content, and reduced protein synthesis. In ex vivo experiments, Cardi-Braun® and del Nido cardioplegia solutions supplemented with GYY4137 significantly reduced the pro-apoptotic protein caspase-3 content and preserved ATP content. Furthermore, GYY4137 supplemented cardioplegia solutions decreased the S-(5-adenosyl)-L-methionine/S-(adenosyl)-L-homocysteine ratio, reducing the oxidative stress in cardiac tissue. Finally, heart beating analysis revealed the preservation of the inter-beat interval and the heart rate in del Nido cardioplegia solution supplemented with GYY4137. CONCLUSIONS GYY4137 preconditioning preserved energetic state during starved conditions, attenuating the cardiomyocytes apoptosis in vitro. The addition of GYY4137 to cardioplegia solutions prevented apoptosis, ATP consumption, and oxidative stress in perfused rat hearts, restoring its electrophysiological status after cardiac arrest. These findings suggested that GYY4137 sulfide donor may improve the cardioplegia solution performance during cardiac surgery.


Assuntos
Apoptose/efeitos dos fármacos , Parada Cardíaca/metabolismo , Coração/efeitos dos fármacos , Sulfeto de Hidrogênio/farmacologia , Miócitos Cardíacos/efeitos dos fármacos , Estresse Oxidativo/efeitos dos fármacos , Trifosfato de Adenosina/metabolismo , Animais , Soluções Cardioplégicas , Caspase 3/metabolismo , Linhagem Celular , Células Cultivadas , Masculino , Miócitos Cardíacos/metabolismo , Ratos , Ratos Wistar
15.
Sci Rep ; 7: 43217, 2017 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-28240274

RESUMO

Panoramic optical mapping is the primary method for imaging electrophysiological activity from the entire outer surface of Langendorff-perfused hearts. To date, it is the only method of simultaneously measuring multiple key electrophysiological parameters, such as transmembrane voltage and intracellular free calcium, at high spatial and temporal resolution. Despite the impact it has already had on the fields of cardiac arrhythmias and whole-heart computational modeling, present-day system designs precludes its adoption by the broader cardiovascular research community because of their high costs. Taking advantage of recent technological advances, we developed and validated low-cost optical mapping systems for panoramic imaging using Langendorff-perfused pig hearts, a clinically-relevant model in basic research and bioengineering. By significantly lowering financial thresholds, this powerful cardiac electrophysiology imaging modality may gain wider use in research and, even, teaching laboratories, which we substantiated using the lower-cost Langendorff-perfused rabbit heart model.


Assuntos
Arritmias Cardíacas/fisiopatologia , Fenômenos Eletrofisiológicos , Coração/fisiopatologia , Imagem Óptica/métodos , Animais , Custos e Análise de Custo , Modelos Biológicos , Imagem Óptica/economia , Análise Espaço-Temporal , Suínos
16.
Pacing Clin Electrophysiol ; 40(2): 145-153, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28070890

RESUMO

BACKGROUND: Information regarding suitability for subcutaneous implantable cardioverter-defibrillator (S-ICD) implant in tetralogy of Fallot (ToF) population is scarce and needs to be further explored. THE AIMS OF OUR STUDY WERE: (1) to determine the proportion of patients with ToF eligible for S-ICD, (2) to identify the optimal sensing vector in ToF patients, (3) to test specifically the eligibility for S-ICD with right-sided screening, and (4) to compare with the proportion of eligible patients in a nonselected ICD population. METHODS: We recruited 60 consecutive patients with ToF and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left arm and right arm electrodes 1 cm right lateral to the xiphoid midline. The Boston Scientific electrocardiogram (ECG) screening tool was utilized. RESULTS: We found a higher proportion of patients with right-sided positive screening in comparison with standard screening (77 ± 0.4% vs. 67 ± 0.4%; P < 0.0001) and a trend to higher number of appropriate leads in right-sided screening (1.3 ± 1 vs. 1.1 ± 1 ms; P = 0.07). Patients who failed the screening had a longer QRS duration and longer QT interval. Standard and right-sided screening showed a higher percent of positive patients in the control group compared to ToF patients (P < 0.001). CONCLUSION: Right-sided screening was associated with a significant 10% increase in S-ICD eligibility in ToF patients. When comparing with an acquired cardiomyopathies group, ToF showed a lower eligibility for S-ICD. The most appropriate ECG vector was the alternate vector in contrast to what is observed in the general population.


Assuntos
Arritmias Cardíacas/prevenção & controle , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Eletrocardiografia/métodos , Implantação de Prótese/estatística & dados numéricos , Tetralogia de Fallot/epidemiologia , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Morte Súbita Cardíaca/epidemiologia , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Seleção de Pacientes , Cuidados Pré-Operatórios/métodos , Prevalência , Prognóstico , Ajuste de Prótese/métodos , Ajuste de Prótese/estatística & dados numéricos , Implantação de Prótese/métodos , Fatores de Risco , Espanha , Tetralogia de Fallot/cirurgia , Resultado do Tratamento
17.
Clin Exp Pharmacol Physiol ; 43(11): 1062-1070, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27501159

RESUMO

JTV-519 is a 1,4-benzothiazepine derivative with multichannel effects that inhibits Ca2+ release from the sarcoplasmic reticulum and stabilizes the closed state of the ryanodine receptor, preventing myocardial damage and the induction of arrhythmias during Ca2+ overload. Mechanical stretch increases cellular Na+ inflow, activates the reverse mode of the Na+ /Ca2+ exchanger, and modifies Ca2+ handling and myocardial electrophysiology, favoring arrhythmogenesis. This study aims to determine whether JTV-519 modifies the stretch-induced manifestations of mechanoelectric feedback. The ventricular fibrillation (VF) modifications induced by acute stretch were studied in Langendorff-perfused rabbit hearts using epicardial multiple electrodes under control conditions (n=9) or during JTV-519 perfusion: 0.1 µmol/L (n=9) and 1 µmol/L (n=9). Spectral and mapping techniques were used to establish the baseline, stretch and post-stretch VF characteristics. JTV-519 slowed baseline VF and decreased activation complexity. These effects were dose-dependent (baseline VF dominant frequency: control=13.9±2.2 Hz; JTV 0.1 µmol/L=11.1±1.1 Hz, P<.01; JTV 1 µmol/L=6.6±1.1 Hz, P<.0001). The stretch-induced acceleration of VF (control=38.8%) was significantly reduced by JTV-519 0.1 µmol/L (19.8%) and abolished by JTV 1 µmol/L (-1.5%). During stretch, the VF activation complexity index was reduced in both JTV-519 series (control=1.60±0.15; JTV 0.1 µmol/L=1.13±0.3, P<.0001; JTV 1 µmol/L=0.57±0.21, P<.0001), and was independently related to VF dominant frequency (R=.82; P<.0001). The fifth percentile of the VF activation intervals, conduction velocity and wavelength entered the multiple linear regression model using dominant frequency as the dependent variable (R=-.84; P<.0001). In conclusion, JTV-519 slowed and simplified the baseline VF activation patterns and abolished the stretch-induced manifestations of mechanoelectric feedback.


Assuntos
Retroalimentação Fisiológica/efeitos dos fármacos , Tiazepinas/uso terapêutico , Fibrilação Ventricular/tratamento farmacológico , Fibrilação Ventricular/fisiopatologia , Animais , Bloqueadores dos Canais de Cálcio/farmacologia , Bloqueadores dos Canais de Cálcio/uso terapêutico , Fenômenos Eletrofisiológicos/efeitos dos fármacos , Fenômenos Eletrofisiológicos/fisiologia , Retroalimentação Fisiológica/fisiologia , Pressorreceptores/efeitos dos fármacos , Pressorreceptores/fisiologia , Coelhos , Canal de Liberação de Cálcio do Receptor de Rianodina/fisiologia , Retículo Sarcoplasmático/efeitos dos fármacos , Retículo Sarcoplasmático/fisiologia , Tiazepinas/farmacologia , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 27(5): 563-70, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26799774

RESUMO

INTRODUCTION: The diagnosis of Brugada syndrome based on the ECG is hampered by the dynamic nature of its ECG manifestations. Brugada syndrome patients are only 25% likely to present a type 1 ECG. The objective of this study is to provide an ECG diagnostic criterion for Brugada syndrome patients that can be applied consistently even in the absence of a type 1 ECG. METHODS AND RESULTS: We recorded 67-lead body surface potential maps from 94 Brugada syndrome patients and 82 controls (including right bundle branch block patients and healthy individuals). The spatial propagation direction during the last r' wave and the slope at the end of the QRS complex were measured and compared between patients groups. Receiver-operating characteristic curves were constructed for half of the database to identify optimal cutoff values; sensitivity and specificity for these cutoff values were measured in the other half of the database. A spontaneous type 1 ECG was present in only 30% of BrS patients. An orientation in the sagittal plane < 101º during the last r' wave and a descending slope < 9.65 mV/s enables the diagnosis of the syndrome with a sensitivity of 69% and a specificity of 97% in non-type 1 Brugada syndrome patients. CONCLUSION: Spatiotemporal characteristics of surface ECG recordings can enable a robust identification of BrS even without the presence of a type 1 ECG.


Assuntos
Potenciais de Ação , Síndrome de Brugada/diagnóstico , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Adulto , Área Sob a Curva , Síndrome de Brugada/fisiopatologia , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Processamento de Sinais Assistido por Computador , Espanha , Fatores de Tempo
19.
J Cardiovasc Electrophysiol ; 27(4): 435-42, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26776725

RESUMO

INTRODUCTION: Ablation of high dominant frequency (DF) sources in patients with atrial fibrillation (AF) is an effective treatment option for paroxysmal AF. The aim of this study was to evaluate the accuracy of noninvasive estimation of DF and electrical patterns determination by solving the inverse problem of the electrocardiography. METHODS: Four representative AF patients with left-to-right and right-to-left atrial DF patterns were included in the study. For each patient, intracardiac electrograms from both atria were recorded simultaneously together with 67-lead body surface recordings. In addition to clinical recordings, realistic mathematical models of atria and torso anatomy with different DF patterns of AF were used. For both mathematical models and clinical recordings, inverse-computed electrograms were compared to intracardiac electrograms in terms of voltage, phase, and frequency spectrum relative errors. RESULTS: Comparison between intracardiac and inverse computed electrograms for AF patients showed 8.8 ± 4.4% errors for DF, 32 ± 4% for voltage, and 65 ± 4% for phase determination. These results were corroborated by mathematical simulations showing that the inverse problem solution was able to reconstruct the frequency spectrum and the DF maps with relative errors of 5.5 ± 4.1%, whereas the reconstruction of the electrograms or the instantaneous phase presented larger relative errors (i.e., 38 ± 15% and 48 ± 14 % respectively, P < 0.01). CONCLUSIONS: Noninvasive reconstruction of atrial frequency maps can be achieved by solving the inverse problem of electrocardiography with a higher accuracy than temporal distribution patterns.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Mapeamento Epicárdico/métodos , Modelos Cardiovasculares , Pericárdio/fisiopatologia , Algoritmos , Simulação por Computador , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Int J Cardiol ; 186: 250-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25828128

RESUMO

BACKGROUND: Early prognosis in comatose survivors after cardiac arrest due to ventricular fibrillation (VF) is unreliable, especially in patients undergoing mild hypothermia. We aimed at developing a reliable risk-score to enable early prediction of cerebral performance and survival. METHODS: Sixty-one out of 239 consecutive patients undergoing mild hypothermia after cardiac arrest, with eventual return of spontaneous circulation (ROSC), and comatose status on admission fulfilled the inclusion criteria. Background clinical variables, VF time and frequency domain fundamental variables were considered. The primary and secondary outcomes were a favorable neurological performance (FNP) during hospitalization and survival to hospital discharge, respectively. The predictive model was developed in a retrospective cohort (n = 32; September 2006-September 2011, 48.5 ± 10.5 months of follow-up) and further validated in a prospective cohort (n = 29; October 2011-July 2013, 5 ± 1.8 months of follow-up). RESULTS: FNP was present in 16 (50.0%) and 21 patients (72.4%) in the retrospective and prospective cohorts, respectively. Seventeen (53.1%) and 21 patients (72.4%), respectively, survived to hospital discharge. Both outcomes were significantly associated (p < 0.001). Retrospective multivariate analysis provided a prediction model (sensitivity = 0.94, specificity = 1) that included spectral dominant frequency, derived power density and peak ratios between high and low frequency bands, and the number of shocks delivered before ROSC. Validation on the prospective cohort showed sensitivity = 0.88 and specificity = 0.91. A model-derived risk-score properly predicted 93% of FNP. Testing the model on follow-up showed a c-statistic ≥ 0.89. CONCLUSIONS: A spectral analysis-based model reliably correlates time-dependent VF spectral changes with acute cerebral injury in comatose survivors undergoing mild hypothermia after cardiac arrest.


Assuntos
Encéfalo/fisiopatologia , Coma/etiologia , Hipotermia Induzida/métodos , Parada Cardíaca Extra-Hospitalar/terapia , Medição de Risco/métodos , Fibrilação Ventricular/terapia , Coma/mortalidade , Coma/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/complicações , Prognóstico , Estudos Prospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Fibrilação Ventricular/complicações , Fibrilação Ventricular/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...